Frequently Asked Question

[Altronix][Lock] [Relay] 6062] 6062
Last Updated 4 years ago

please see attachment.

Special note:

  • TRG: has one wire coming from the door station or triggering device.
    • [Red wire (if its a BE cat 5 system) from the door station lock connector is the sole one needed]; [Yellow wire (if its an MT 2-wire system) from the door station lock connector is the sole one needed]; for the IP system please refer to the following link: https://www.becaudio.com/ticket.system/upload/kb/faq.php?cid=28
  • GND (-): there are three wires.
    • [Green wire (if its a BE cat 5 system) from the door station]
    • [ground from the 12vDC]
    • [ground from the lock]
  • 12v (+):
    • [positive from the 12vDC]
    • [C connector of the 6062]
  • NO:
    • [positive side from the lock]
  • C:
    • bridge to the 12v (+)
  • NC:
    • empty

6062 DIP code:

  1. dip code 1 OFF
  2. dip code 2 ON
  3. dip code 3 ON
  4. dip code 4 ON

6062 PSU is shared with the door station 12vDC. This is not permitted. The 6062 should have it's own 12vDC PSU separate from the 12vDC feeding the door station.