Frequently Asked Question
MT-Troubleshooting?
Last Updated 7 years ago
- Replace monitor with working one
- If working, check dip-switches on original monitor otherwise, warranty (Dip Switches on pg. 4 – MT Manual)
- If not working, perform local test with fresh wire (18awg/2-conductor, stranded, unshielded) connecting Door Station, Separator, Distributor and PSU
- If good, check wiring distances or possible short in the wire-run. (Wiring Distances on pg. 3 – MT Manual)
- If not, bypass 2-4, connect monitor directly to “monitor bus” at the MT-202
- If good, warranty the 2-4
- If not, check voltage at power supply (~24vDC), adjust if needed.
- Possible Replace – MT-202/Door Station
- If working, check dip-switches on original monitor otherwise, warranty (Dip Switches on pg. 4 – MT Manual)
-
- …on multiple/all monitors?
- Check voltage @ Power Supply & both buses @ MT-202 (~24vDC)
- Check impedance switch @ MT-2-4 (Should be ON at the last 2-4 in the line)
- Take one monitor and test it direct to MT-202 monitor bus
- If good, replace MT-2-4
- If still not working, replace MT-202/Door Station
- If good, replace MT-2-4
- Check voltage @ Power Supply & both buses @ MT-202 (~24vDC)
- …on multiple/all monitors?
- No Audio…
- ...to/from the outdoor panel
- …at one monitor
- Check volume controls (on the side and on back)
- If not, replace with a working monitor –
- If working monitor is good, replace monitor
- If working monitor is not working, check wiring
- If working monitor is good, replace monitor
- Perform local test with 18awg/2-conductor, stranded, unshielded wiring –
- If working, there is a short or misconnection in the wiring
- If not working, replace door panel
- If working, there is a short or misconnection in the wiring
- Check volume controls (on the side and on back)
- …at multiple monitors
- Check volume controls (on the side and on back)
- If monitors are on the same 2-4, check one monitor direct to MT-202
- If working, check wiring to 2-4 from bus, otherwise replace 2-4
- If not working, is the power separator led lit
- Yes – Replace 202
- No – Check power supply connections V+/V-
- Yes – Replace 202
- If working, check wiring to 2-4 from bus, otherwise replace 2-4
- If monitors are out on separate 2-4’s, try working monitors at each malfunctioning location
- If working monitor is good, replace monitor
- If working monitor is not working, check wiring.
- If working monitor is good, replace monitor
- Perform local test with 18awg/2-conductor, stranded, unshielded wiring –
- If working, there is a short or misconnection in the wiring
- If not working, replace door panel
- If working, there is a short or misconnection in the wiring
- Check volume controls (on the side and on back)
- …at one monitor
- ...to/from the outdoor panel
- …at all monitors
- Check wiring from door station
- Perform local test with 18awg/2-conductor, stranded, unshielded wiring –
- If working, there is a short or misconnection in the existing wiring
- If not working, replace door panel
- If working, there is a short or misconnection in the existing wiring
- Check wiring from door station
- No Ringtone…
- …at monitor
- Check a working monitor at that location
- If working, replace monitor.
- If not working, check impedance switch (should be ON at last 2-4) & voltage at MT-202 monitor bus (24vDC)
- If okay, replace monitor
- If okay, replace monitor
- If working, replace monitor.
- Check a working monitor at that location
- …at door panel
- Check that switch 7 is on at the monitor
- If on and still not working, check wiring –
- Perform local test with 18awg/2-conductor, stranded, unshielded wiring -
- If working, there is a short or misconnection in the existing wiring
- If not, replace door panel
- If working, there is a short or misconnection in the existing wiring
- If on and still not working, check wiring –
- Check that switch 7 is on at the monitor
- …at monitor
- Strike does not…
- …open
- Ensure you have a 12vDC lock
- Check the 6-pin connector wires (for an NO lock, use RED and YELLOW wires, for an NC lock, use BLUE and YELLOW)
- Apply direct voltage to lock contacts
- If not working, replace strike
- If strike is working, check voltage from BLUE and YELLOW wires (should be 12v) and check to make sure jumper “SIP1” is in place at 2+3 or 1+2
- If voltage is too low, or 0v, replace door station
- If voltage is too low, or 0v, replace door station
- If not working, replace strike
- Ensure you have a 12vDC lock
- …open for long enough
- Change dip switches 4 + 5 at the door station (see manual pg. 5)
- Check voltage at BLUE and YELLOW wires.
- …buzz
- DC Strikes do not buzz, AC Strikes do but require an Altronix 6062 relay and their own dedicated power source to use with the BEC video system.
- Change dip switches 4 + 5 at the door station (see manual pg. 5)
- …open