Frequently Asked Question

[MT-PS][MT-202][MT-2-4][MT-5B][MT-5W][MT-7B][MT-7W][MT-IP10W]- MT-Series Distances
Last Updated 6 years ago

If you install the system where there are less than 20 units/monitors:

  • distance from door station to MT-202 (the power separator): 196' if using 18/2 wire
    • distance from door station to MT-202 (the power separator): 262' if using 16/2 wire
  • distance from MT-202 to MT-2-4 (the last Branch Controller): 196' if using 18/2 wire
    • distance from MT-202 to MT-2-4 (the last Branch Controller): 196' if using 16/2 wire
  • distance from MT-2-4 to the MT Monitor: 98' if using 18/2 wire
    • distance from MT-2-4 to the MT Monitor: 131' if using 16/2 wire

If you install the system where there more than 20+ units/monitors:

  • distance from door station to MT-202 (the power separator): 262' if using 16/2 wire
  • distance from MT-202 to MT-2-4 (the last Branch Controller): 196' if using 16/2 wire
  • distance from MT-2-4 to the MT Monitor: 131' if using 16/2 wire

Please Wait!

Please wait... it will take a second!