Magnetic Lock Wiring Instructions Instructions
- (A.) 12VDC Input:
- Required power 0.5 Amp (Minimum).
- Connect the positive (+) lead from a 12VDC power source to V+.
- Connect the ground (-) lead from a 12VDC power source to V- .
- Check jumper for 12VDC operation.
- (B.) 24VDC Input:
- Require Power 0.25 Amp (minimum).
- Connect the positive (+) lead from a 24VDC power source to V+.
- Connect the ground (-) lead from a 24VDC power source to V- .
- Check jumper for 24VDC operation.
- (C.) Contacts:
- Relay dry contacts are rated 1Amp at 24VDC for safe operation, do not exceed this rating.
- If you require a normally open switch, connect the wires from the system to COM and NO.
- If yo~ require a normally closed switch, connect the wires from the system to COM and NC.
Important! .
If power switch is not wired between DC source voltage and magnet, it will take a longerĀ time:to de-energize the magnet simulating residual magnetism. (see below)
Printed Circuit Board Schematic
Power selector
12VDC or
24VDC input
Lock status sensor
1. Normally open switch: NO and COM
2. Normally 'closed switch: NC and COM
Important: Please Read Before Attempting To Install Magnetic Lock
- (A.) Handle the equipment with care, damaging the mating surfaces of the magnet or
armature plate may reduce locking efficiency. - (B.) The magnet mounts rigidly to the door frame, the armature plate mounts to the door
with hardware. Kit provided that allows it to pivot about its center to compensate for
door wear and misalignment. - (C.) Template use must take place with door in its normally closed position.
- (D.) Before installing, please add thread locker to all screws. Firmly tighten screws to
avoid fastening loosen.
Typical Installation:
**Important: fix the armature plate not too tightly, and make the rubber washer more
flexible, in order to make the armature plate automatically adjust its proper position with the magnet.
MOUNTING INSTRUCTION
STEP 1
- FOLD TEMPLATE ALONG DOTTED LINE.
- PLACE TEMPLATE AGAINST DOOR AND HEAD FRAME .
- DRILL HOLES AS INDICATED ON TEMPLATE.
STEP2
- MOUNT THE ARMATURE PLATE TO DOOR USING 1 RUBBER WASHER SANDWICHED BETWEEN 2 STEEL WASHER (THE RUBBER WASHER AND 2 STEEL WASHERS ARE INSTALLED ON THE THROUGH SESNUT BETWEEN THE ARMATURE PLATE AND DOOR).
STEP3
- INSTALL THE MOUNTING PLATE.
- ADJUST THE MOUNTING PLATE SO THAT IT AND THE ARMATURE PLATE FORM A
RIGHT ANGLE. - USING THE MOUNTING PLATE AS A TEMPLATE, DRILL THE WIRE HOLE .
- DRILL AND INSTALL THE REMAINING MOUNTING SCREWS.
STEP4
- INSTALL MAGNET TO MOUNTING PLATE WITH 2 M4(M6)SCREWS SUPPLIED.
STEPS
- INSTALL ELECTRICAL WIRING PER INSTRUCTION SHEET.
STEP6
- TEST ALL FUNCTIONS OF THIS MODEL (SEE WIRING INSTRUCTION).