[NT-IP-A9K] to connect to a door strike. [with/without Altronix 6062 switch]
Last Updated 7 years ago
see attached images for visual details.
We recommend the use of the 6062 Altronix Relay Switch
We recommend the use of the 6062 Altronix Relay Switch
- NT-IP-A9K w-6062-01
- In this diagram, your 12vDC power adapter that goes to the NT-IP-A9K [Red & Black ] wire.
- The same [Black] from the NT-IP-A9K goes to connect to the GND of the 6062 Altronix Relay switch
- the same [Black] from the 15v Plug-In that came with the relay connects to the 6062 relay switch.
- and that same [Black] goes to on end of the electric door strike.
- The [Yellow] from the NT-IP-A9K goes to connect to the TRG of the 6062 Altronix Relay switch
- The same [Red] from the 15v Plug-In that came with the relay goes to connect to the 12V & to the C of the 6062 Altronix Relay switch
- From the 6062 Altronix Relay switch the [Green] connects from the NO to the other end of the electric door strike.
- Ensure that 1 on the 6062 Altronix Relay switch is on, and pin 2-3-&4 are off.